BATTERY MANAGEMENT SYSTEM (SILICON
BMS™)
|
|
The
SILICON BMS was designed in 1989 with all the different specifications and
tenders in mind. Silicon Engineering took all the available specifications at
the time and wrote software to accommodate all our customers
|
|
 |
|
|
|
The numerous battery technologies (Plante, Tubular, Flat plate, High Antmony,
Low Antmony, Vartabloc, Semi-Sealed, VRLA, lead calcium, Ni-Cad pocket, Sealed
Ni-Cad available today are less tolerant of incorrect charger settings and
operator abuse than in the past. These reflect in shorter service life and
higher maintenance requirements with degrading of system reliability. |
|
|
|
The SILICON BMS is a control and monitoring system for
battery chargers to ensure the correct battery manufacturer's settings are
applied to the battery charger. The SILICON BMS alarms when any condition is abnormal or
out of specification. The SILICON BMS improves DC system reliability and optimises
battery service life while reducing maintenance to a minimum. SILICON BMS is fully
automatic and is ideal for remote or difficult to maintain battery sites or
where battery expertise is limited. |
|
|
|
Download the upgrade Instruction Manual from previous BMS to SILICON BMS™
Plus |
 |
|
Features: System
Manufacturer approved
settings of most stationary battery technologies are built-in.
Status of complete system
displayed on LCD. DC & AC voltages, currents, timers, alarms.
Reconfigure a battery
change in under 60 seconds - and know all settings are correct.
Charging protocol set for
each battery type - auto-boost (Y/N), alarm values, timers etc.
Adjustment menu is
password protected - no unauthorised tampering of settings.
Password may be customer
changed.
Event Recorder stores 2000
events on a FIFO basis.(First-in First-out). Click here
for alarm codes
You can check the results
of battery test over past month. Up to 100 different types of events logged.
Plug-in universal module
for all units 5Amp to 1000Amp, 24Volt to 220Volt DC.
One BMS can handle one
battery and single or dual chargers.
Hardware equipped for
remote communication and SCADA.
Suitable for driving most
single & three phase analogue thyristor control cards and upgrades.
LCD display backlit for
easy reading in poor light. (Auto turnoff after 10 min.)
Y2K compliant.
Mature software (approx 1000 in service since 1989). Older units are software upgradable. |
|
|
Features: Alarms
Every alarm you could
wish for is already included as standard. (Up to 21 alarms)
Alarms displayed locally
on LCD, remote isolated C/O relays, audio beeper and RS232.
Intelligent alarm
analysis. BMS decides whether Major (come NOW) or Minor.
Alarms digitally set for
alarm value and reset value.(eg. Mains fail set=180 Reset=198V)
BMS logic stops load test
during mains failure or after test circuit failure.
Earth fault alarm
indicates polarity and value of leakage impedance to earth.
Boost timer override
& load test fail alarms are latched until manual reset.
Alarm settings may be
customer adjusted (with password access).
Alarm relay adjustable
operating time delay (default 30 seconds).
Local LED indication for
non-skilled staff warning.
Keypad testing facility
of alarm relays - fast & safe. |
|
|
Features: Self Test & Protection.
Self test on power up.
Integrated watchdog timer
to prevent system latch up.
Battery automatic periodic
load test by turning off the charger & applying a dummy load.
Load test circuit
components are self tested. Any internal fault is alarmed.
Intelligent application of
extra load in sites with high standing loads.
Automatic return to Float
from Boost in the shortest possible time - extend battery life.
Manual lamp test. |
|
|